Send inquiry
Mineral Water Reverse Osmosis Purification System
Reverse osmosis is a kind of membrane separation technology developed since the 1980s. It mainly uses the osmosis principle of semitransparent membrane. A pressure that is called reverse osmosis. The device that is composed of reverse osmosis components is called reverse osmosis device.
Working Principle
1.A semi permeable membrane in a reverse osmosis system only allows certain things to pass through.
2.This membrane passes water easily but also prevents many other contaminants from passing by trapping them.
3.Water is normally on both sides of the membrane, the water on each side has a different concentration of dissolved minerals.
4.The water in the less concentrated solution tries to dilute the more concentrated solution.
5.Water will pass through the membrane from the lower concentration side to the greater concentration side.
6.The osmotic pressure (see diagram) created by the difference in water levels, will counter the diffusion process forming an equilibrium between the two sides.
Features
1.Raw water TDS≤500(design as per your raw water condition)
2.Produced water TDS≤5-10 (design as per your raw water condition)
3.water temperature 5°C~45°C
4.Rate of desalination≥98%-99%
5.Recovery rate: 50-60<%
Reverse osmosis is a kind of membrane separation technology developed since the 1980s. It mainly uses the osmosis principle of semitransparent membrane. A pressure that is called reverse osmosis. The device that is composed of reverse osmosis components is called reverse osmosis device.
Working Principle
1.A semi permeable membrane in a reverse osmosis system only allows certain things to pass through.
2.This membrane passes water easily but also prevents many other contaminants from passing by trapping them.
3.Water is normally on both sides of the membrane, the water on each side has a different concentration of dissolved minerals.
4.The water in the less concentrated solution tries to dilute the more concentrated solution.
5.Water will pass through the membrane from the lower concentration side to the greater concentration side.
6.The osmotic pressure (see diagram) created by the difference in water levels, will counter the diffusion process forming an equilibrium between the two sides.
Features
1.Raw water TDS≤500(design as per your raw water condition)
2.Produced water TDS≤5-10 (design as per your raw water condition)
3.water temperature 5°C~45°C
4.Rate of desalination≥98%-99%
5.Recovery rate: 50-60<%
Model | Output(ton per hour) |
Motor power (kw) |
Membrane |
Entrance Diameter (mm) |
Size(L*W*H) ( mm) |
Weight (Kg) |
RO-0.5 | 500 | 1.1 | 4040 | 32 |
1200*600*2100 1500*900*1800 |
500 |
RO-1 | 1 | 1.5 | 4040 | 32 |
1200*600*2100 1500*900*1800 |
800 |
RO-2 | 2 | 3 | 4040 | 38 |
2000*800*2200 2500*900*2000 |
1200 |
RO-3 | 3 | 4 | 8040 | 38 |
2600*900*2300 2600*1000*2200 |
1600 |
RO-4 | 4 | 5 | 8040 | 51 |
2000*900*2300 1600*1000*2200 |
2000 |
RO-6 | 6 | 11 | 8040 | 51 |
2200*1000*2400 2600*1000*2200 |
2500 |
RO-9 | 9 | 16 | 8040 | 51 |
2400*1200*2600 3500*1000*2300 |
3000 |
RO-12 | 12 | 21 | 8040 | 51 |
2800*1400*2600 5600*1000*2300 |
4000 |