Negotiable
The date of payment from buyers deliver within days
Hebei
Long-term effective
2017-12-03 02:08
250
Company Profile
Hebei Kaixiang Electrical Technology Co., Ltd.By certification [File Integrity]
Contact:Mr. Bruce(Mr.)
Email:
Telephone:
Area:Hebei
Address:Hebei
Website: http://kxload.hzyjmx.com/
AC 400V PF 0.8 RL Dummy Load Bank 214KVA
1.Product Introduction
AC 400V PF 0.8 RL Dummy Load Bank 214KVA
It is composed of outdoor resistor-inductance AC load bank,data collection
system,electric control module,thermal module,control part etc.It can accurately detect Marine generator output power
and load capacity,and assist shipyard in acceptance of vessel,mooring test,sea trial,load test,static voltage characteristic
test, speed characteristic test,overload protection test,reverse power and reverse current protection test,and parallel
operation test etc.
2.AC 400V PF 0.8 RL Dummy Load Bank 214KVA System Chart
3.AC 400V PF 0.8 RL Dummy Load Bank 214KVA Working Environment
Altitute:≤2500m
Temperature:-10°C~50°C
Humidity:≤95%RH
Working Mode:Continuous work(>6hours continuous long-term work per day)
4.AC 400V PF 0.8 RL Dummy Load Bank 214KVA Technical Specifications
Technical parameter | |
AC400-214KVA-RL | |
Rated voltage /Frequency |
AC Three-phase four-wire 400V,50/60Hz |
Rated Capacity |
214KVA |
Load Distribution |
Resistive load:171.1KW,Inductive load:131.1KVA |
Stepping Value |
Resistive load: 0.1KW Inductive load: 0.1Kvar |
Resistor divider file |
Resistive load: 0.1(0.01~0.1), 1(0.1~1), 1, 2, 2, 5, 10, 10, 20, 20, 50, 50kW 12steps |
Reactance file |
Inductive laod: 0.1(0.01~0.1), 1(0.1~1), 1, 2, 2, 5, 10, 20, 20, 20, 50kvar 12steps |
Power factor |
0.8 |
Load Tolerance(each step) |
±5% |
Load Tolerance(overall) |
±3% |
Display Precision |
0.5 class |
Control Power Supply |
External AC single phase connection 220V/50Hz |
Wire Connection |
Load power supply input--Copper bar (star coupling) Control power supply input--Connector-bar |
Insulation grade |
F class |
Duty cycle |
Continuous |
Cooling |
Forced air cooling, Horizontal inlet air, Vertical cooling |
Transportation |
Hoisting, there are lifting lug in top of casing and casters in bottom of load bank |
Casing Color |
Grey(RAL7035) |
Operating Environment Parameter | |
Ambient Temperature |
-10ºC~+50ºC |
Relative Humidity |
≤95% |
Altitude |
≤2500 meters |
Atmospheric Pressure |
86~106kPa |
Main components brand | |
Contactor |
Schneider |
Circuit Breaker |
Siemens |
Fuse |
Delixi |
SCM |
Infineon |
Alloy Resistor |
Kaixiang |
Data Management Software |
Kaixiang |
5.AC 400V PF 0.8 RL Dummy Load Bank 214KVA Product Display
Overall Apperance