Model Number |
TENGCON T-907 (16Thermocouple input) tengcon plc |
||
Physical Feature | |||
Dimension |
169 x 134 x 63 mm (W x H x D) |
||
Weight |
0.5 Kg |
||
Mount |
Standard rail or bolts |
||
Working Temperature |
From -40ºC to 85 ºC |
||
I/O Feature | |||
Built-in analog inputs |
16 Thermocouple input In support of the thermocouple type :K,J,T,E,R,S,B,N |
||
Input signal |
Thermocouple |
||
I/O state indicators |
44 pcs. |
||
Indicators |
overflow:flash,disconnection:off,normal:on |
||
Protection |
Link-loss detecting |
||
Measurement Range |
K(-1000~13500), J(-1000~12500),T(0~4500),E(0~10500) ,R(0~16500) , S(0~16500,B(0~18500) ,N(0~13500) Exceeds the Minimum:-2730 Exceeds the Maximum:30000 Disconnection:32767 |
||
Conversion cycle |
10ms |
||
Power Supply and power output | |||
Power Supply |
Rated Voltage |
220V AC or 24V DC |
|
Range |
From 90V AC to 250V AC, 50Hz, or 24V DC |
||
Rated current |
40mA/220VAC(24V DC output in full-load) 14mA/220VAC( 24V DC output in no-load) |
||
Isolated power output |
Rated voltage |
24VDC |
|
Rated current |
0.2A |
||
Output resistance |
About 20 Ohm |
||
Terminals |
VOUT(24V+, 24V-) |
||
Communication | |||
Ethernet |
1 port (RJ45, 10M/100M adaptive,MODBUS TCP protocol) |
||
RS232 |
1 port (COM0, for internal test) |
||
RS232/485 |
2 port l COM2, DB9 RS232 direct connect l COM1, DB9 RS485(pin 2 is B, pin 3 is A) Default settings: MODBUS RTU Slave, Bode rate 19200,1,8,E, address 1 |
||
CAN |
1 port |
||
DIP |
8-bits Set DIP ON will force the IP address to the default 192.168.1.99 |
||
Run/stop switch |
2 switches run/stop(in stop mode, only PLC program stopped) |
||
Communication indicator |
6 pcs. l RUN indicator(flashing) l COM1 COM2serial port communication indicator(flashing when communicating) l CAN port communication indicator l LINK Ethernet linking indicator DATA Ethernet communicating indicator |
||
Memory | |||
User program memory size |
2M Byte |
||
User data memory size |
2M Byte |
||
Back-up battery data memory |
1K Byte |
||
Data back-up time |
1 year |
||
CPU feature | |||
CPU frequency |
48 MHz |
Max. 72 MHz |
|
Minimum instruction processing time |
4 millisecond |
|
|
INT and Bit operation |
From 1 to 4 microsecond |
|
|
Floating-point algorithm |
About 40 microsecond |
|
|
1ms timer quantity |
No limit |
|
|
Clock |
Internal clock |
Back-up battery |
Order Requirements:
Please confirm and choose the following information when you are ready to place order :
Working Power Supply |
220V AC 50HZ |
Please confirm which one |
9-36V DC | ||
Communication |
1 RS485 port,1RS232 port (default setting) |
Please confirm which one
|
2 RS485 port | ||
Quantity |
|